Difference between revisions of "Richtwaarden en vuistregels (tabbelarium)"
From BK Wiki
Mjvgrootveld (Talk | contribs) (Created page with '{| border=1 |minimum vereiste hoeveelheid ventilatielucht ||bij niet roken: 20 m<sup>3</sup>/h per persoon || |- | ||bij roken: 30 m<sup>3</sup>/h per persoon ||&nbs…') |
Frschnater (Talk | contribs) |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{| border=1 | {| border=1 | ||
− | |minimum vereiste hoeveelheid ventilatielucht | + | !scope="row"|minimum vereiste hoeveelheid ventilatielucht |
||bij niet roken: 20 m<sup>3</sup>/h per persoon | ||bij niet roken: 20 m<sup>3</sup>/h per persoon | ||
|| | || | ||
Line 10: | Line 10: | ||
|- | |- | ||
− | |CO<sub>2</sub>-productie van de mens | + | !scope="row"|CO<sub>2</sub>-productie van de mens |
||20 l/h | ||20 l/h | ||
|| | || | ||
Line 16: | Line 16: | ||
|- | |- | ||
− | |waterdampproductie van de mens | + | !scope="row"|waterdampproductie van de mens |
||50 g/h | ||50 g/h | ||
|| | || | ||
Line 22: | Line 22: | ||
|- | |- | ||
− | |warmteproductie van de mens | + | !scope="row"|warmteproductie van de mens |
||100W | ||100W | ||
|| | || | ||
Line 28: | Line 28: | ||
|- | |- | ||
− | |warmtecapiciteit van lucht | + | !scope="row"|warmtecapiciteit van lucht |
||ρc<sub>lucht</sub> = 1200 J/m<sup>3</sup>K | ||ρc<sub>lucht</sub> = 1200 J/m<sup>3</sup>K | ||
|| | || | ||
Line 34: | Line 34: | ||
|- | |- | ||
− | |noodzakelijke oppervlak ventilatieopeningen bij geventileerd dak | + | !scope="row"|noodzakelijke oppervlak ventilatieopeningen bij geventileerd dak |
||f<sub>vent</sub> ≥ 0,7 * v<sub>sp</sub> * δ m<sup>2</sup>/m' dakrand | ||f<sub>vent</sub> ≥ 0,7 * v<sub>sp</sub> * δ m<sup>2</sup>/m' dakrand | ||
|| | || | ||
Line 49: | Line 49: | ||
|- | |- | ||
− | |dampovergangsweerstanden | + | !scope="row"|dampovergangsweerstanden |
||R<sub>di</sub> = 40*10<sup>6</sup> m/s | ||R<sub>di</sub> = 40*10<sup>6</sup> m/s | ||
|| | || | ||
Line 61: | Line 61: | ||
|- | |- | ||
− | |warmteovergangsweerstanden | + | !scope="row"|warmteovergangsweerstanden |
||r<sub>i</sub> = 0,13m<sup>2</sup> K/W | ||r<sub>i</sub> = 0,13m<sup>2</sup> K/W | ||
|| | || | ||
Line 73: | Line 73: | ||
|- | |- | ||
− | |goede dampremmende laag | + | !scope="row"|goede dampremmende laag |
||μd ≥ 20m | ||μd ≥ 20m | ||
|| | || | ||
Line 79: | Line 79: | ||
|- | |- | ||
− | |frequentie-afhankelijke dikte van een afdekfolie voor absorptiemateriaal opdat het nog akoestisch trasparant is | + | !scope="row"|frequentie-afhankelijke dikte van een afdekfolie voor absorptiemateriaal opdat het nog akoestisch trasparant is |
||2πfρd ≤ 400 | ||2πfρd ≤ 400 | ||
|| | || | ||
Line 99: | Line 99: | ||
|- | |- | ||
− | |doorsnede zon | + | !scope="row"|doorsnede zon |
||1 391 000 km | ||1 391 000 km | ||
|| | || | ||
Line 105: | Line 105: | ||
|- | |- | ||
− | |doorsnede aarde (evenaar) | + | !scope="row"|doorsnede aarde (evenaar) |
||12 755 km | ||12 755 km | ||
||waarde | ||waarde | ||
Line 111: | Line 111: | ||
|- | |- | ||
− | |gemiddelde afstand zon-aarde | + | !scope="row"|gemiddelde afstand zon-aarde |
||149 600 000 km | ||149 600 000 km | ||
||410 | ||410 | ||
Line 117: | Line 117: | ||
|- | |- | ||
− | |rendement verwarmingsketels | + | !scope="row"|rendement verwarmingsketels |
||80 - 85 % | ||80 - 85 % | ||
||462 | ||462 | ||
Line 123: | Line 123: | ||
|- | |- | ||
− | |relatie kubieke uitz.coëff. - lineaire | + | !scope="row"|relatie kubieke uitz.coëff. - lineaire |
||voor vaste lichamen : γ = 3 α | ||voor vaste lichamen : γ = 3 α | ||
||670 | ||670 | ||
Line 129: | Line 129: | ||
|- | |- | ||
− | |uitz.coëff. | + | !scope="row"|uitz.coëff. |
||voor ideale gassen : γ = 1/273 | ||voor ideale gassen : γ = 1/273 | ||
||6,625*10<sup>-34</sup> | ||6,625*10<sup>-34</sup> | ||
Line 135: | Line 135: | ||
|- | |- | ||
− | |golflengtegebiedjes bestreken door de diverse kleuren | + | !scope="row"|golflengtegebiedjes bestreken door de diverse kleuren |
||violet : 380 - 420 nm | ||violet : 380 - 420 nm | ||
||5,67*10<sup>-8</sup> | ||5,67*10<sup>-8</sup> |
Latest revision as of 09:43, 26 May 2014
minimum vereiste hoeveelheid ventilatielucht | bij niet roken: 20 m3/h per persoon | ||
---|---|---|---|
bij roken: 30 m3/h per persoon | |||
CO2-productie van de mens | 20 l/h | ||
waterdampproductie van de mens | 50 g/h | ||
warmteproductie van de mens | 100W | ||
warmtecapiciteit van lucht | ρclucht = 1200 J/m3K | ||
noodzakelijke oppervlak ventilatieopeningen bij geventileerd dak | fvent ≥ 0,7 * vsp * δ m2/m' dakrand | ||
vsp = gemiddelde luchtsnelheden spouw in m/s | |||
δ = spouwbreedte in m | |||
dampovergangsweerstanden | Rdi = 40*106 m/s | ||
Rda = 7*106 m/s | |||
warmteovergangsweerstanden | ri = 0,13m2 K/W | ||
ra = 0,04m2 K/W | |||
goede dampremmende laag | μd ≥ 20m | ||
frequentie-afhankelijke dikte van een afdekfolie voor absorptiemateriaal opdat het nog akoestisch trasparant is | 2πfρd ≤ 400 | ||
f = hoogste frequentie waarvoor geen verstoing mag optreden | |||
ρ = dichtheid van het folie in kg/m3 | |||
d = dikte van het folie in m | |||
doorsnede zon | 1 391 000 km | ||
doorsnede aarde (evenaar) | 12 755 km | waarde | dimensie |
gemiddelde afstand zon-aarde | 149 600 000 km | 410 | kg/m2s |
rendement verwarmingsketels | 80 - 85 % | 462 | J/kgK |
relatie kubieke uitz.coëff. - lineaire | voor vaste lichamen : γ = 3 α | 670 | lm/W |
uitz.coëff. | voor ideale gassen : γ = 1/273 | 6,625*10-34 | Ws2 |
golflengtegebiedjes bestreken door de diverse kleuren | violet : 380 - 420 nm | 5,67*10-8 | W/m2K4 |
blauw : 420 - 495 nm | 341 | m/s | |
groen : 495 - 566 nm | 3*108 | m/s | |
geel : 566 - 589 nm | 9,81 | m/s2 | |
oranje : 589 - 627 nm | 23*10-6 | m2/s | |
rood : 627 - 780 nm |